Some AI-generated content may be used to demonstrate platform features during beta

civ_pioneer9210d

Soil-cement column grid collides with fibre duct during widening – chevron or shallow columns?

Eight-hundred-millimetre soil-cement columns on one-metre centres reinforce a widening near a live fibre duct sitting 0.9 m off drawing. The city wants zero outage risk. Options: chevron grid, shallow columns over the duct, or hand-placed flowable fill. If you swerved mid-grid, how did you keep geotech, utility, and scheduler all smiling?
4

Comments (13)

FA
fatima.cities9 days ago
Press release trumpeted uninterrupted fibre for 3 000 homes, spinning an engineering pivot as a community win.
PA
parker.jungle9 days ago
Spray-paint the chevron grid so crews place columns without late-night tape measure confusion.
BE
benji_ee9 days ago
Satellite SMS numbers on site; cell drops inside the cut walls can delay safety calls.
DE
deeptank.pm9 days ago
Keep binder at fourteen percent in the top metre; clay up there still needs chemistry.
SI
sitaspecs9 days ago
Cost plus five percent, schedule minus ten days compared with relocating the duct. Logged as classic value-engineering.
JO
joe.bridges10 days ago
Night drilling means binder cools; raise silo temperature in the method statement or viscosity spikes.
ZO
zoe.assetlife10 days ago
Install an access pit now; future splice ease beats later digging.
FR
francesca.struct10 days ago
Eight vibrating-wire gauges on the duct fed live microstrain to the utility’s SCADA; peace of mind in one graph.
HP
hp.consulting10 days ago
Insurance rider disappeared once the grid moved clear of the duct; underwriter feared a fibre hit.
TE
tendai_supplychain10 days ago
Binder order dropped fifteen tonnes after the chevron tweak; one phone call cancelled an extra silo rental.
AN
angie_structural10 days ago
Column depth over the gas line shrank from 8 m to 4 m; we thickened the slab 60 mm with mesh to compensate.
MK
mkale.codes10 days ago
A Plaxis parametric bowl made the utility engineer approve in one meeting; visuals beat tables.
TE
terra.solid10 days ago
Chevron grid at 1.3 m centres in a V around the duct held settlement under 5 mm. Topped with a 200 mm rich-asphalt strip for stiffness correction.

We use cookies

We use cookies to enhance your browsing experience, serve personalized ads or content, and analyze our traffic. By clicking "Accept All", you consent to our use of cookies. Read our Cookie Policy to learn more.